Some operations can be performed to make the diaphragm pressure gauge run again when it is not turned on.
Diaphragm pressure gauge is suitable for measuring the pressure of liquid, gas or steam without explosion danger, crystallization, solidification and high viscosity, but without corrosion to copper and copper alloys.
The heating and hot water supply of a house depends entirely on its diaphragm pressure gauge system, especially in the cold winter. Diaphragm pressure gauges are an indispensable part of any house, which means that they must always be in good Z condition. When the diaphragm pressure gauge fails, it may bring you many problems. If you find that your diaphragm pressure gauge is not turned on, you can perform some operations to make it run again.
1. Power supply
First of all, you B must check the power supply of the diaphragm pressure gauge. This sounds obvious, but many times the owner forgets to check whether his diaphragm pressure gauge has been turned on. The power supply problem is closely related to the main circuit board tripping or fuse blowing, which means that it needs to be reset. Those who can't find the reset button on the diaphragm pressure gauge can refer to the user manual provided by the diaphragm pressure gauge manufacturer. Tenants can contact the landlord to obtain the manual of diaphragm pressure gauge.
2. Reset button
Diaphragm pressure gauges usually have a built-in reset button to ensure the safety of an. If the diaphragm pressure gauge does not work, it may be because it tripped, which may require a simple reset to make the diaphragm pressure gauge work normally. Diaphragm pressure gauge manufacturers usually put the reset button on the front of the diaphragm pressure gauge when designing it, so as to be easy to locate in an emergency. However, if the reset button of the diaphragm pressure gauge is not in front of the diaphragm pressure gauge, you can check the manufacturer's manual to find out the location. Usually, the reset button of diaphragm pressure gauge is a dial, which needs to be reset to "0" before it is turned on again.
3. Heating control
Heating control is an important part of any diaphragm pressure gauge system. These include timers, thermostats in rooms and programmers for diaphragm pressure gauges. B All these controls shall be set accordingly to make the diaphragm pressure gauge system run normally. However, these controls sometimes confuse customers. In this case, check the instruction manual of diaphragm pressure gauge to ensure that all settings are correct. Some controls in the diaphragm pressure gauge can send signals remotely, which may cause the diaphragm pressure gauge to stop running. Just press the wrong button to stop the diaphragm pressure gauge, so please make sure to check all diaphragm pressure gauges before calling the engineer.
4, diaphragm pressure gauge gas supply
Few people know this, but the gas supply in the house will also lead to the accidental failure of the diaphragm pressure gauge system. This is especially true for houses equipped with card system payment meters. If you run out of credit, the diaphragm pressure gauge will stop automatically because the gas is turned off. This is why it is important for you to always recharge and re-insert the card, so that the diaphragm pressure gauge can operate normally without any interference.
5. System pressure
Sometimes, the system pressure of the diaphragm pressure gauge may become lower, which will also cause the diaphragm pressure gauge to stop running unexpectedly. This is very common in the combined diaphragm pressure gauge, and the dial of the combined diaphragm pressure gauge shows from 1 to 4. If the pressure drops below 1 bar, the diaphragm pressure gauge will not work. Similarly, the system pressure should always be 1bar, and the diaphragm pressure gauge can play a good Z level. If you have tried all these methods but failed, then if we have installed the diaphragm pressure gauge for you, it is time to contact the barrier-free diaphragm pressure gauge, otherwise, please contact your an engineer for inspection.
6. The condensate pipe may freeze, which may cause the diaphragm pressure gauge to fail to start.
Condensed water is a normal by-product of diaphragm pressure gauge, which is generated when heat is generated. This condensed water will automatically be discharged into the indoor or outdoor drainage pipe. Unprotected condensate pipes or improperly installed condensate pipes will freeze under the J-end condition, resulting in the diaphragm pressure gauge not working normally. Z it is good to install condensation pipes in the house to avoid freezing. Sometimes this is not possible, in which case, you can place a pipe to discharge it to an external drain. In this case, B shall install the pipeline according to the manufacturer's instructions, and the pipeline shall be of appropriate size and insulated to prevent icing.
7. The fan in diaphragm pressure gauge needs to be replaced.
Exhaust gas B produced by diaphragm pressure gauge must be completely released. There is a fan in your diaphragm pressure gauge, which pushes the exhaust gas to the outside of the house through a pipe called flue, where it is completely released into the air by an. The flue is very similar to the exhaust pipe on a car. If your fan stops working for some reason, your diaphragm pressure gauge will not work, so the fan is an important AN full function. Replacing the fan is simple, but the installer first needs to investigate why the fan doesn't work properly.
8. There is sludge in your system.
Sludge is the material that settles to the bottom of diaphragm pressure gauge (usually radiator). This will reduce the operating efficiency of your diaphragm pressure gauge and may lead to the failure of diaphragm pressure gauge components. Sludge is usually produced by injecting air into the system. This will rust the inside of the radiator. Sludge accumulates at the bottom of the radiator, and sometimes on the parts (such as pumps) in the diaphragm pressure gauge. You can tell that there is sludge in the system. Cold spots usually appear at the bottom of the radiator. Make the system run as efficiently as possible. Qualified installers need to use chemical cleaners or powerful flushing agents or both to remove sludge.
9. There is air in your system.
Diaphragm pressure gauges should contain only water. There is air in your system. Because this will cause problems or threats, B must delete it. In order to make the system run as efficiently as possible, only water should exist in the pipes and radiators. If there is air in your system, it will not work efficiently. You often notice this by making noise in the radiator, otherwise the top of the radiator will get cold. Your installer should investigate the cause of air accumulation in the system. They can usually solve the problem easily by radiating radiators.